Scale bv bleed area
f) Scale & bleed areas to a KYB DFF 12.5 rod for comparison |
|
|
|
Scale bleed areas to KYB DFF 12.5 |
|
|
- As a general rule, default bv comp clickers are about in the middle of the range.
- For example, (2151f) 2013 YZ 250, default bv clicker is:
bc-10 which = 1.18 mm2 flow area at that clicker position
- For a quick comparison, we have scaled the bv stem cHole on the bikes below
to the equivalent of KYB DFF 12.5 rod.
- The purpose is then to find each forks bc-clicker setting that most closely
matches 1.18 mm2 (highlighted in yellow below).
- This gives a bv clicker setting and flow area that is comparable between all bikes.
- The click range flow area factor is 1.30 (1.18 x 1.3 = 1.51) (1.18 / 1.3 = .93).
- We are making the assumption that 130% is a reasonable range of adjustment with 6-8 clicks available in either direction.
- [The values below are fixed and do not change]
|
rec_id |
|
|
1638f 04 RM 250 12 rod |
bc-6 is close to 1.18 mm2, |
but gives a limited |
click range of 4 - 6 - 8 |
|
Showa DFF |
2.60 stk chole dia (5.3 mm2) |
2.50 bott ndl dia (4.9 mm2) |
5.3 - 4.9 = .40 mm2 diff * |
|
.98 |
[aver 160%] |
bc-4 |
1.24 |
|
bc-6 |
1.50 |
153% |
bc-8 |
|
3531f 10 CRF 250 12.5 rod |
The cHole is much larger than the |
bott ndl dia resulting in 2.17 mm2 |
flow at bc-1 |
|
Showa DFF |
2.40 stk chole dia |
1.75 bott ndl dia |
2.11 mm2 area diff * |
|
2.17 |
|
bc-1 |
2.63 |
|
bc-10 |
3.04 |
140% |
bc-20 |
|
3791f 10 CRF SC 250 12.5 rod |
With a 1.95 mm insert, |
bc-12 is close to 1.18 mm2 |
with a good click range of 6 - 12 - 20 |
|
Showa DFF |
1.95 mod insert |
1.75 bott ndl dia |
.58 mm2 area diff |
|
.89 |
|
bc-6 |
1.19 |
|
bc-12 |
1.54 |
173% |
bc-20 |
|
3253f 15 XCF 350 8 rod |
The 4CS kit needle was designed to |
work with the 8mm rod, but gives a |
fairly tight click range of 15 - 20 - 26 |
|
4CS DFF |
1.78 mod chole dia 4CS kit |
1.77 bott ndl dia |
. 03 mm2 area diff |
|
.93 |
|
bc-15 |
1.20 |
|
bc-20 |
1.51 |
163% |
bc-26 |
|
3509f 19 SXF 350 12 rod |
As per below, we should just use the |
stk bv stem cHole and set default |
bc-12 |
|
AER SFF |
2.04 stk chole dia |
1.91 bott ndl dia |
.40 mm2 area diff |
|
.90 |
|
bc-6 |
1.19 |
|
bc-12 |
1.56 |
173% |
bc-20 |
|
3509f 19 SXF 350 12 rod |
We have used 1.95 insert w/bc-16, |
now it looks like we should have set |
to bc-21, or used stk cHole above |
|
AER SFF |
1.95 mod insert |
1.91 bott ndl dia |
.12 mm2 area diff |
|
.90 |
|
bc-15 |
1.18 |
|
bc-21 |
1.51 |
168% |
bc-29 |
|
2151f 13 YZ 250 12.5 rod |
Baseline for comparison |
We are simply using this as a |
fixed point to compare against |
|
KYB DFF |
2.07 stk chole dia |
1.80 bott ndl dia |
.83 mm2 area diff * |
|
.93 |
|
bc-3 |
1.18 |
|
bc-10 |
1.51 |
162% |
bc-20 |
|
4108f 22 CRF 450 14 rod |
The cHole is larger than bott ndl dia, |
resulting in 2.25 mm2 flow at bc-1 |
Stk, there is minimal adjustment of |
11% above and below default bc-8 |
|
Showa SFF |
2.42 stk chole dia |
1.53 bott ndl dia |
2.77 mm2 area diff |
|
2.25 |
|
bc-1 |
2.50 |
|
bc-8 |
2.75 |
122% |
bc-16 max |
|
4108f 22 CRF 450 14 rod |
We tested 1.99mm insert, but found |
that 1.95 as per below gives a better |
default clicker setting |
|
Showa SFF |
1.99 mod insert |
1.525 bott ndl dia |
|
1.06 |
|
bc-1 |
1.17 |
|
bc-4 |
1.56 |
147% |
bc-16 |
|
4108f 22 CRF 450 14 rod |
Proposed with reasonable click |
click range of 1 - 7 - 16 |
Note there are only 16 clicks max |
|
Showa SFF |
1.95 proposed insert |
1.525 bott ndl dia |
|
.91 |
|
bc-1 |
1.17 |
|
bc-7 |
1.46 |
153% |
bc-16 max |
|
 |
 |
 |