- HOW TO REVERSE ENGINEER BV COMP FORCE (IN THIS EXAMPLE)
- GET c-zeta from database
- Calculate k.spring = spr.rate x 2.20462 x 25.4 x 12
- Calculate c.damp = ( c.zeta x lev.ratio . SQRT (4 x m.wheel x k.spring / 32.2) / 12 ) / 2
- Calculate bv force = ( vel x c.damp )
|